Ultrasound Research - Screening, Diagnosis, Pregnancy, Detection

Ultrasound Research Today is a free monthly online journal that collates and summarizes the latest research about Ultrasound, including details on screening, diagnosis, pregnancy, detection.


Ultrasound Research Today

Home

View Latest Issue

Information About Ultrasound

Books on Ultrasound

Advertising in Research Today

View Other Research Today Publications



Meta-analysis of angiographic versus intravascular ultrasound parameters of drug-eluting stent efficacy (from TAXUS IV, V, and VI).

Escolar E, Mintz GS, Popma J, Michalek A, Kim SW, Mandinov L, Koglin J, Stone G, Ellis SG, Grube E, Dawkins KD, Weissman NJ

Cardiovascular Research Institute/Medstar Research Institute, Washington Hospital Center, Washington, DC, USA.

Both quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS) are currently used to assess in-stent restenosis. This study aimed to use standardized imaging and clinical follow-up to compare QCA parameters with several IVUS parameters to evaluate their strengths and weaknesses for detecting in-stent restenosis in a drug-eluting stent population. A subset of patients from the TAXUS IV, V, and VI studies was evaluated. The subset, which included 216 TAXUS-treated patients and 191 bare-metal stent-treated patients, had complete IVUS and QCA performed at baseline and follow-up. As expected, all QCA and IVUS parameters were consistent with less intimal hyperplasia in TAXUS patients than controls. The overall incidence of QCA binary restenosis was 14.0%, which was 9.3% in TAXUS-treated patients and 19% in bare-metal stent-treated patients (p = 0.0008). Regression analysis showed that QCA late lumen loss and percentage of diameter stenosis correlated only moderately with the various IVUS measures of neointimal hyperplasia for the combined group of patients (TAXUS + bare-metal stent), as well as for the TAXUS-treated and bare-metal stent-treated patients separately. However, in general, correlations within the control (bare-metal stent) group tended to be stronger than within the TAXUS group. The strongest correlation was between QCA percentage of diameter stenosis and IVUS percentage of intimal hyperplasia in the overall group and the control group. The strongest IVUS predictor of QCA binary restenosis at 9 months was maximum percentage of intimal hyperplasia, with an overall C = 0.91 and p <0.001. In conclusion, the QCA and IVUS parameters used to evaluate drug-eluting stent efficacy showed a moderate correlation with IVUS percentage of intimal hyperplasia, reliably predicting QCA binary in-stent restenosis.

Published 16 August 2007 in Am J Cardiol, 100(4): 621-6.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Ultrasound Research Today. All Rights Reserved.



Ultrasound Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)



Ultrasound Books

Small Animal Diagnostic Ultrasound

Small Animal Diagnostic Ultrasound