Accuracy of electrocardiographic-gated versus nongated volumetric intravascular ultrasound measurements of coronary arterial narrowing.

Jensen LO, Thayssen P

Department of Cardiology, Odense University Hospital, Odense, Denmark. okkels@dadlnet.dk

Intravascular ultrasound (IVUS) allows precise measurements of plaque plus media (P+M) volume and neointimal hyperplasia after coronary artery stenting. Conventional IVUS volumetric analysis is performed mostly without electrocardiographically gated acquisition, and the IVUS images are selected at 1-mm intervals, whereas the electrocardiographically gated approach consists of images in end-diastole. The accuracy in the luminal, P+M, and external elastic membrane (EEM) volumes between 2 pullbacks with the electrocardiographically gated and nongated approaches has not previously been compared. In 15 patients, 19 segments were studied with electrocardiographically gated and nongated IVUS systems. Two identical pullbacks were performed with each system using the same IVUS catheter. Volumes of the lumen, EEM, and P+M obtained using the electrocardiographically gated pullback technique did not differ significantly from the corresponding volumes obtained using the nongated pullback technique (lumen: 109.7 +/- 47.7 vs 109.2 +/- 45.0 mm(3), p = NS; EEM: 242.6 +/- 109.2 vs 235.0 +/- 108.1 mm(3), p = NS; P+M: 134.8 +/- 67.7 vs 129.8 +/- 69.1 mm(3), p = NS). No significant differences were seen in changes between 2 electrocardiographically gated and 2 nongated pullbacks (lumen: 0.37 +/- 1.76 vs -0.23 +/- 2.32 mm(3), p = NS; EEM: 0.25 +/- 3.22 vs -0.94 +/- 4.27 mm(3), p = NS; P+M: -0.18 +/- 3.42 vs -0.74 +/- 3.88 mm(3), p = NS). In conclusion, in moderate atherosclerotic or stented coronary arteries, electrocardiographically gated IVUS acquisition is not superior in accuracy to conventional nongated IVUS acquisition.

Published 15 January 2007 in Am J Cardiol, 99(2): 279-83.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Ultrasound Research Today. All Rights Reserved.



Ultrasound Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Ultrasound Books

The Physics of Radiation Therapy

The Physics of Radiation Therapy