Role of biplane and biplane echocardiographically guided 3-dimensional echocardiography during dobutamine stress echocardiography.

Yang HS, Pellikka PA, McCully RB, Oh JK, Kukuzke JA, Khandheria BK, Chandrasekaran K

Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905, USA.

Image acquisition time and wall-motion score of conventional 2-dimensional (2D) dobutamine stress echocardiography (DSE) were compared with those of biplane and 3-dimensional (3D) DSE in 50 patients (age 67 +/- 13 years) with regular rhythms during clinically indicated DSE. Commercially available systems were used for the study. We used a conventional transducer for 2D and a matrix-array transducer (x4 or x3-1) for two biplane (60- and 120-degree) images and one 3D full-volume image. Image quality was scored as 1 = good; 2 = adequate; and 3 = inadequate. Segmental wall-motion scores for each method were analyzed in blinded fashion. Acquisition times of biplane (9.3 +/- 2.8 seconds) and biplane-guided 3D (additional 2.6 +/- 1.0 seconds) echocardiography were significantly shorter than those of conventional 2D DSE (60.0 +/- 26.7 seconds) (P < .001). Image quality was adequate or good in 94% for biplane and 96% for 3D echocardiography. Agreement of segmental wall-motion score was present in 87.6% of segments for 2D versus biplane and 85.9% for 2D versus 3D at baseline and in 88.0% for 2D versus biplane and 87.4% for 2D versus 3D at peak stress. Acquisition of biplane or biplane-guided 3D volumetric data during DSE with use of a new matrix-array transducer was feasible and shortened image acquisition time without affecting the diagnostic yield compared with conventional 2D imaging.

Published 4 September 2006 in J Am Soc Echocardiogr, 19(9): 1136-43.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Ultrasound Research Today. All Rights Reserved.



Ultrasound Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)



Ultrasound Books

Breast Ultrasound

Breast Ultrasound