View Other Research Today Publications



Optimisation of 20 kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results.

Klíma J, Frias-Ferrer A, González-García J, Ludvík J, Sáez V, Iniesta J

J. Heyrovský Insitute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejskova 3, 182 23 Prague 8, Czech Republic. klima@jh-inst.cas.cz

The intensity distribution of the ultrasonic energy is, after the frequency, the most significant parameter to characterize ultrasonic fields in any sonochemical experiment. Whereas in the case of low intensity ultrasound the measurement of intensity and its distribution is well solved, in the case of high intensity (when cavitation takes place) the measurement is much more complicated. That is why the predicting the acoustic pressure distribution within the cell is desirable. A numerical solution of the wave equation gave the distribution of intensity within the cell. The calculations together with experimental verification have shown that the whole reactor behaves like a resonator and the energy distribution depends strongly on its shape. The agreement between computational simulations and experiments allowed optimisation of the shape of the sonochemical reactor. The optimal geometry resulted in a strong increase in intensity along a large part of the cell. The advantages of such optimised geometry are (i) the ultrasonic power necessary for obtaining cavitation is low; (ii) low power delivered to the system results in only weak heating, consequently, no cooling is necessary and (iii) the "active volume" is large, i.e. the fraction of the reactor volume with high intensity is large and is not limited to a vicinity close to the horn tip.

Published 29 August 2006 in Ultrason Sonochem, 14(1): 19-28.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Ultrasound Research Today. All Rights Reserved.



Ultrasound Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)



Ultrasound Books

Nuclear Medicine and PET/CT Technology and Techniques (Nuclear Medicine and PET)

Nuclear Medicine and PET/CT Technology and Techniques (Nuclear Medicine and PET)