Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy.

Suffoletto MS, Dohi K, Cannesson M, Saba S, Gorcsan J

The Cardiovascular Institute, University of Pittsburgh, Pittsburgh, PA 15213-2582, USA.

BACKGROUND: Mechanical dyssynchrony is a potential means to predict response to cardiac resynchronization therapy (CRT). We hypothesized that novel echocardiographic image speckle tracking can quantify dyssynchrony and predict response to CRT. METHODS AND RESULTS: Seventy-four subjects were studied: 64 heart failure patients undergoing CRT (aged 64+/-12 years, ejection fraction 26+/-6%, QRS duration 157+/-28 ms) and 10 normal controls. Speckle tracking applied to routine midventricular short-axis images calculated radial strain from multiple circumferential points averaged to 6 standard segments. Dyssynchrony from timing of speckle-tracking peak radial strain was correlated with tissue Doppler measures in 47 subjects (r=0.94, P<0.001; 95% CI 0.90 to 0.96). The ability of baseline speckle-tracking radial dyssynchrony (time difference in peak septal wall-to-posterior wall strain > or =130 ms) to predict response to CRT was then tested. It predicted an immediate increase in stroke volume in 48 patients studied the day after CRT with 91% sensitivity and 75% specificity. In 50 patients with long-term follow-up 8+/-5 months after CRT, baseline speckle-tracking radial dyssynchrony predicted a significant increase in ejection fraction with 89% sensitivity and 83% specificity. Patients in whom left ventricular lead position was concordant with the site of latest mechanical activation by speckle-tracking radial strain had an increase in ejection fraction from baseline to a greater degree (10+/-5%) than patients with discordant lead position (6+/-5%; P<0.05). CONCLUSIONS: Speckle-tracking radial strain can quantify dyssynchrony and predict immediate and long-term response to CRT and has potential for clinical application.

Published 21 February 2006 in Circulation, 113(7): 960-8.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Ultrasound Research Today. All Rights Reserved.



Ultrasound Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)



Ultrasound Books

Essentials of Ultrasound Physics: The Board Review Book

Essentials of Ultrasound Physics: The Board Review Book