Ultrasound Research - Screening, Diagnosis, Pregnancy, Detection

Ultrasound Research Today is a free monthly online journal that collates and summarizes the latest research about Ultrasound, including details on screening, diagnosis, pregnancy, detection.


Ultrasound Research Today

Home

View Latest Issue

Information About Ultrasound

Books on Ultrasound

Advertising in Research Today

View Other Research Today Publications



Functional and morphologic imaging of coronary atherosclerosis in living mice using high-resolution color Doppler echocardiography and ultrasound biomicroscopy.

Wikström J, Grönros J, Bergström G, Gan LM

Department of Physiology, Institute of Physiology and Pharmacology, The Sahlgrenska Academy, Göteborg University, Sweden.

OBJECTIVES: This study aimed to establish non-invasive methods of assessing coronary artery morphology in normal and atherosclerotic mice in vivo. BACKGROUND: Coronary flow velocity reserve (CFVR) has been shown to correlate with coronary minimal lumen diameter (MLD) in patients with coronary artery stenosis. In mice, there are no existing non-invasive imaging techniques allowing quantitative measurement of the coronary artery morphology and function. METHODS: Systemic hemodynamic effects of adenosine were studied in seven C57BL/6 mice. In 17 C57BL/6 mice, CFVR was measured in the mid left coronary artery (LCA) using either hypoxia- or adenosine-induced coronary hyperemia. Further, in another 10 atherosclerotic low-density lipoprotein receptor (LDLR)-/- mice, the hypoxia-induced CFVR was performed and proximal LCA MLD was measured using ultrasound biomicroscopy (UBM). Histologic sections of the LCA were collected. RESULTS: The adenosine dose of 160 microg/kg/min induced maximal coronary hyperemia without any systemic hemodynamic effects. Adenosine and hypoxia-induced CFVR values averaged at 2.0 +/- 0.1 and 1.9 +/- 0.3, respectively, in C57BL/6 mice (p = NS). In LDLR-/- mice, CFVR and MLD ranged between 1.4 to 2.9 microm and 190 to 370 microm, respectively. Histology revealed proximal lumen-narrowing plaques in the LCA. Significant correlation was found between hypoxia-induced CFVR and the MLD (p < 0.005, R2 = 0.8707). CONCLUSIONS: The CDE and UBM technique can be used to measure atherosclerosis-related lumen narrowing of the LCA in living mice. These non-invasive techniques may provide us with novel tools for following up disease status in mouse coronary arteries in a quantitative manner.

Published 15 August 2005 in J Am Coll Cardiol, 46(4): 720-7.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Ultrasound Research Today. All Rights Reserved.



Ultrasound Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Ultrasound Books

Radiation Protection in Medical Radiography

Radiation Protection in Medical Radiography